Emergency Lighting Installation: A Guide for Businesses and Landlords

Last updated 21 November 2026

Emergency lighting switches on automatically when the normal lighting fails, so people can leave a building safely. Most non-domestic premises, and the shared areas of flats and HMOs, need it where the fire risk assessment says so under the Regulatory Reform (Fire Safety) Order 2005. Systems are designed to BS 5266-1, wired to BS 7671 and tested monthly and annually. We install emergency lighting across Blackpool and the Fylde and give free quotations.

Emergency lighting comes on automatically when the normal lighting fails, so that people can find their way out of a building safely and can locate firefighting equipment and fire alarm call points. In most non-domestic premises it is an important part of fire safety, and it needs to be designed, installed and maintained properly. This guide explains who needs it, how systems are designed and installed, what testing and certificates are needed and what affects the cost.

Who needs emergency lighting

In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 applies to most non-domestic premises and to the common parts of blocks of flats and houses in multiple occupation. It requires the responsible person to make sure that emergency routes and exits are indicated by signs and, where necessary, provided with emergency lighting of adequate intensity in case the normal lighting fails. Whether emergency lighting is needed, and how much, should be decided through the fire risk assessment for the premises.

Typical premises include offices, shops, factories and warehouses, hotels and guest houses, pubs and restaurants, schools, care homes and the shared stairs and corridors of flats and HMOs.

The main types of emergency lighting

Emergency lighting is a general term that covers several things:

  • Escape route lighting, which lights the routes people use to leave the building.
  • Open area lighting, sometimes called anti-panic lighting, which helps people move safely through larger spaces towards an escape route.
  • High risk task area lighting, which allows people to make dangerous processes safe before they leave.
  • Exit signs, which show the way out and may be illuminated.

Fittings can be maintained, meaning they are lit all the time and stay on when the power fails, or non-maintained, meaning they only light when the normal supply fails. Systems can use self-contained fittings with their own batteries or a central battery system that feeds several fittings.

Design and standards

Emergency lighting in the UK is designed to BS 5266-1, the code of practice for emergency lighting, together with related standards on lighting levels and system operation. The design should consider escape routes, changes of direction and level, exit doors, firefighting equipment, fire alarm call points, first aid points and any high risk areas. How long the system must run after a power failure depends on the premises and how they are used, and is set out in the design.

The wiring must also comply with BS 7671. A good design starts with a survey of the building and the fire risk assessment, rather than simply replacing what was there before.

Installation

Installing emergency lighting usually involves:

  • surveying the premises and agreeing the design;
  • fitting the luminaires and exit signs in the right positions;
  • connecting them to the relevant local lighting circuits, so that they come on if that circuit fails, not only if the whole building loses power;
  • providing a way to test the system, such as key switches or an automatic test system;
  • commissioning the system and checking that each fitting works for the required duration.

Where emergency lighting is added to an occupied building, the work can be planned around opening hours to keep disruption to a minimum.

Testing and maintenance

Once installed, emergency lighting has to be tested regularly. In general, that means a short functional test each month and a full duration test each year, with the results recorded in a logbook, and the responsible person must make sure this happens. Our blog post on emergency lighting testing explains what the routine involves. Batteries and lamps have a limited life, so fittings that fail their tests need attention promptly.

Certificates and records

After installation, you should receive certification confirming that the system has been designed, installed and commissioned in line with the standard, along with the electrical certificate for the wiring. These documents, together with the logbook and test records, are what a fire risk assessor, insurer or enforcing authority may ask to see. If you are not sure whether an existing system has the right paperwork, an inspection can establish its condition.

Upgrading an existing system

Older systems may have fittings that no longer suit the building, for example after a change of layout or use, or batteries that no longer last for the required duration. A change in how a building is used, such as converting offices into flats, can also change what is needed. An upgrade may involve replacing fittings, adding coverage to escape routes that were missed, or moving to an automatic testing system to make record keeping easier. The fire risk assessment should be reviewed whenever a building changes.

What affects the cost

The cost of an emergency lighting installation depends on:

  • the size and layout of the building and the number of escape routes;
  • the number and type of fittings and signs needed;
  • whether the fittings are self-contained or fed from a central battery;
  • whether a manual or automatic testing system is chosen;
  • how easy it is to reach ceilings and run wiring;
  • whether existing fittings can be kept or need replacing.

We do not publish set prices, because every building is different. We quote after understanding the premises and the fire risk assessment, and quotations are free.

Working alongside fire alarms

Emergency lighting and fire alarms often go together. We also design, install and maintain fire alarm systems, so the two can be planned at the same time. Our commercial electrician page covers the wider range of work we do for businesses, and our guide to electrical safety for landlords covers duties in rented homes.

Talk to us

If you need emergency lighting installed or upgraded in Blackpool, the Fylde or Preston, call 01253 364101 or send us a message.

Frequently asked questions

Is emergency lighting a legal requirement?

For most non-domestic premises and the common parts of flats and HMOs, the Regulatory Reform (Fire Safety) Order 2005 requires emergency routes and exits to have emergency lighting where necessary. The fire risk assessment decides what is needed.

How often should emergency lighting be tested?

In general, a short functional test each month and a full duration test each year, with the results recorded in a logbook. The system design and manufacturer's instructions may set out further checks.

What is the difference between maintained and non-maintained emergency lighting?

Maintained fittings are lit all the time and stay lit when the power fails. Non-maintained fittings only light when the normal supply fails. Which is used depends on the premises and how they are used.

Do the shared areas of flats need emergency lighting?

Often, yes. The common parts of blocks of flats and HMOs fall under the Fire Safety Order, and the fire risk assessment decides whether emergency lighting is needed and where.

What is an emergency lighting certificate?

It is the documentation confirming that a system has been designed, installed and commissioned in line with BS 5266-1, together with the records of periodic inspection and testing. Assessors and insurers may ask to see it.